Septiflow Septum Walled Single Line Circuit

Altech Septiflow patented breathing circuit with double lumen divided by a colored septum wall and patented water trap with integrated needle-free connector is designed to prevent water accumulation in the expiratory line, which is a negative effect of low flow anesthesia and long-term intensive care admissions.

The needle-free connectors on the patented water trap allow the infected fluid accumulated in the circuit to be discharged from the system with injectors without contacting healthcare workers or other patients.

  • It traps the water accumulated in the circuit due to condensation.
  • Prevents cross contamination risk by draining the contaminated water trap content in a closed system.

Fully Closed Ventilation

Thanks to the design of the patented water trap with needle-free connector that does not need to be opened to the ambient air, the breathing circuit is not opened to the outside during invasive ventilation and the negative effects of Sepsis and VAP (Ventilator Related Pneumonia) and prolonged hospital stay are prevented. In addition, the fact that the water trap does not open to the ambient air prevents the decrease of PEEP (Positive End Expiratory Pressure) pressure, thus maintaining the patient's oxygenation and average airway pressure. Thanks to the 360 ​​degree rotatable patient connection, the water trap position can be adjusted according to the surgical supine or prone position.

Fully closed system breathing circuits protect especially healthcare personnel, patients, ventilators and anesthesia devices from diseases with high contagiousness; It has a vital function in preventing these diseases from passing on to the next patients.

Single Breathing Circuit for Pediatric and Adult Patients

It can be used in all patients weighing more than 4.5 kg. Thus, a more effective stock management can be fulfilled with a single product code.

Natural Heating

While the septiflow transfers the heat in expiration to the inspiratory line, it naturally warms and humidifies the inhaled air; It reduces your need for heat and moisture filters. Thus, both the ideal breathing temperature is provided for the patient and the efficiency of the anesthetic gases used increases.

Safer at Low Flow

Integrated CO2 sampling line enables end-tidal CO2 measurement via capnography device; Thus, the risk of breathing again in low flow anesthesia is eliminated.

Light Weight, Low Resistance

Polyethylene light Single Hose Line in corrugated structure creates less torque effect on the artificial respiratory tract of the patient. Altech Septiflow is 25% lighter than conventional double line circuits.

The longitudinal division of the circuit reduces compliance and increases the total volume to the patient. The values ​​obtained with the adjusted values ​​are exactly the same.


Click to view the catalogue!
Septiflow Septum Walled Single Line Circuit
NEWS
Curabitur lobortis ultrices mollis. In venenatis lacinia quam a pellentesque.